Description
Overview
Grundfos CR, CRI, and CRN are non-self-priming vertical multistage centrifugal pumps designed with an in-line suction and discharge layout at the same horizontal level. Supplied in 50 Hz IEC configurations across nominal flow sizes 1s through 255, these pumps cover clean water pressure boosting, boiler feed, industrial washing, cooling loops, and reverse osmosis feed.

Features
- In-line one-pipe installation: Inlet and outlet ports sit at the same level with identical pipe dimensions for compact vertical mounting.
- Three wetted-material tiers: CR combines cast-iron pump heads/bases with EN 1.4301 (AISI 304) hydraulics, CRI uses EN 1.4408 (CF 8M) pump heads/bases with AISI 304 internals, and CRN puts all wetted parts in EN 1.4401 / EN 1.4408 (AISI 316 / CF 8M) stainless steel.
- Cartridge mechanical shaft seal: Fitted as standard with an HQQE or HQQV balanced O-ring cartridge seal (silicon carbide/silicon carbide faces with EPDM or FKM elastomers) for service without disassembling the chamber stack.
- IE4 motor efficiency: Equipped with 2-pole totally enclosed fan-cooled Grundfos MG motors (0.37 to 18.5 kW) or Innomotics motors (22 to 200 kW) in IP55 enclosure, insulation class F.
- Thrust-handling device (THD): Factory-fitted on motors 75 kW and larger so standard ball bearings absorb axial impeller thrust.
- ErP ecodesign compliance: Benchmark MEI >= 0.70 across sizes CR 1-3, 3-3, 10-3 through 255-3.

Technical Data
Product range and hydraulic limits across sizes 1s through 20 (50 Hz IEC):
| Pump Size | 1s | 1 | 3 | 5 | 10 | 15 | 20 |
|---|---|---|---|---|---|---|---|
| Rated flow rate [m³/h] | 0.8 | 1 | 3 | 5 | 10 | 15 | 20 |
| Flow rate range [m³/h] | 0.3 - 1.1 | 0.7 - 2.4 | 1.2 - 4.5 | 2.5 - 8.5 | 5 - 13 | 9 - 24 | 11 - 29 |
| Liquid temperature [°C] (standard) | -20 to +120 | -20 to +120 | -20 to +120 | -20 to +120 | -20 to +120 | -20 to +120 | -20 to +120 |
| Max. pump efficiency [%] | 35 | 48 | 58 | 66 | 70 | 72 | 72 |
| Max. operating pressure [bar] | 21 | 22 | 24 | 24 | 22 | 23 | 25 |
| High pressure on request (CRN) [bar] | - | 47 | 41 | 47 | 44 | 47 | 48 |
| Motor power [kW] | 0.37 - 1.1 | 0.37 - 2.2 | 0.37 - 3 | 0.37 - 5.5 | 0.37 - 7.5 | 1.1 - 15 | 1.1 - 18.5 |
| Flange connection (standard) | DN 25 / DN 32 | DN 25 / DN 32 | DN 25 / DN 32 | DN 25 / DN 32 | DN 40 | DN 50 | DN 50 |
| Oval flange (CR, BSP) | Rp 1 | Rp 1 | Rp 1 | Rp 1 1/4 | Rp 1 1/4 | Rp 2 | Rp 2 |
| PJE coupling (CRI/CRN) | DN 32 (48.3 mm) | DN 32 (48.3 mm) | DN 32 (48.3 mm) | DN 32 (48.3 mm) | DN 50 (60.3 mm) | DN 50 (60.3 mm) | DN 50 (60.3 mm) |
Product range and hydraulic limits across heavy-duty sizes 32 through 255 (50 Hz IEC):
| Pump Size | 32 | 45 | 64 | 95 | 125 | 155 | 185 | 215 | 255 |
|---|---|---|---|---|---|---|---|---|---|
| Rated flow rate [m³/h] | 32 | 45 | 64 | 95 | 125 | 155 | 185 | 215 | 255 |
| Flow rate range [m³/h] | 15 - 40 | 22 - 58 | 30 - 85 | 45 - 120 | 60 - 160 | 75 - 200 | 92 - 240 | 108 - 280 | 128 - 330 |
| Min. liquid temperature [°C] | -30 | -30 | -30 | -20 | -20 | -20 | -20 | -20 | -20 |
| Max. liquid temperature [°C] | 120 | 120 | 120 | 120 | 120 | 120 | 120 | 120 | 120 |
| Max. pump efficiency [%] | 78 | 79 | 80 | 81 | 82 | 82 | 82 | 84 | 84 |
| Max. pressure [bar] (standard) | 28 | 33 | 22 | 36 | 39 | 39 | 35 | 32 | 28 |
| High pressure on request (CRN) [bar] | 50 | 49 | 41 | - | - | - | - | - | - |
| Motor power [kW] | 1.5 - 30 | 3 - 45 | 4 - 45 | 5.5 - 90 | 11 - 132 | 11 - 160 | 18.5 - 200 | 22 - 200 | 30 - 200 |
| Flange connection | DN 65 | DN 80 | DN 100 | DN 100 | DN 150 | DN 150 | DN 200 | DN 200 | DN 200 |
| PJE coupling (CRN) | DN 80 (88.9 mm) | DN 100 (114.3 mm) | DN 100 (114.3 mm) | DN 100 (114.3 mm) | DN 150 (168.3 mm) | DN 150 (168.3 mm) | DN 200 (219.1 mm) | DN 200 (219.1 mm) | DN 200 (219.1 mm) |
Note: Special versions extend liquid temperatures down to -40 °C and up to +180 °C (oils up to +240 °C) on request. For CR 95-155, standard max operating pressure is 25 bar (CRN 95-155 up to 40 bar).

Materials and Construction
Wetted and structural materials for CR, CRI, and CRN 1s–20:
| Component | CR 1s–20 | CRI 1s–20 | CRN 1s–20 |
|---|---|---|---|
| Pump head | Grey cast iron EN-GJL-200 | Stainless steel EN 1.4408 (CF 8M) | Stainless steel EN 1.4408 (CF 8M) |
| Base | Grey cast iron EN-GJL-250 | Stainless steel EN 1.4408 (CF 8M) | Stainless steel EN 1.4408 (CF 8M) |
| Impeller, chamber & sleeve | Stainless steel EN 1.4301 (AISI 304) | Stainless steel EN 1.4301 (AISI 304) | Stainless steel EN 1.4401 (AISI 316) |
| Pump shaft | 1.4401 (1s–5) / 1.4057 (10–20) | 1.4401 (1s–5) / 1.4057 (10–20) | 1.4401 (1s–5) / 1.4460 (10–20) |
| Neck ring | PTFE | PTFE | PTFE |
| Shaft seal faces | Silicon carbide / silicon carbide | Silicon carbide / silicon carbide | Silicon carbide / silicon carbide |
| Elastomers (O-rings) | EPDM or FKM | EPDM or FKM | EPDM or FKM |
For sizes 32–64, CR uses ductile cast iron EN-GJS-500-7 pump heads/bases with carbon-graphite-filled PTFE neck rings, while CRN 32–64 uses EN 1.4408 (CF 8M) heads/bases and EN 1.4462 duplex shafts. For sizes 95–255, neck rings upgrade to PEEK, bearing rings to tungsten carbide/tungsten carbide, and shafts (125–255) to duplex stainless steel EN 1.4462.
Shaft Seal Operating Limits
Standard balanced cartridge shaft seals (HQQE/HQQV/HQBE/HQBV) cover both 0.37–55 kW and 75–200 kW motor ranges:
| Standard Shaft Seal | Description | Liquid Temperature [°C] |
|---|---|---|
| HQQE | O-ring cartridge, balanced, silicon carbide / silicon carbide, EPDM | -40 to +120 |
| HQQV | O-ring cartridge, balanced, silicon carbide / silicon carbide, FKM | -20 to +90 |
| HQBE | O-ring cartridge, balanced, silicon carbide / carbon, EPDM | 0 to 120 |
| HQBV | O-ring cartridge, balanced, silicon carbide / carbon, FKM | 0 to 90 |
Connections and Ordering Code

Grundfos type key example (CRE 32-3-2 A-F-A-E-HQQE):
- Type range & flow:
CR,CRI, orCRN(Edenotes integrated frequency converter), followed by rated flow (1sto255m³/h), number of impellers, and reduced-diameter impellers. - Pipe connection:
A(Oval flange),B(NPT thread),CA(FlexiClamp),CX(TriClamp),F(DIN flange),FE(EN 1092-1 type E),G(ANSI flange),J(JIS flange),P(PJE Victaulic-type coupling). - Supply voltage (50 Hz):
3 x 220-230/380-400 V(0.37–1.5 kW),3 x 380-400/660-690 V(2.2–18.5 kW),3 x 380-420/660-725 V(22–200 kW), or single-phase1 x 220-230/240 V(0.37–2.2 kW).
Specify Grundfos CR, CRI, or CRN model code, stage count, connection type, shaft seal variant, supply voltage, and quantity when requesting a quotation.