Description

Overview

Grundfos CR, CRI, and CRN are non-self-priming vertical multistage centrifugal pumps designed with an in-line suction and discharge layout at the same horizontal level. Supplied in 50 Hz IEC configurations across nominal flow sizes 1s through 255, these pumps cover clean water pressure boosting, boiler feed, industrial washing, cooling loops, and reverse osmosis feed.

Grundfos CR, CRI, and CRN 1s to 64 vertical multistage centrifugal pump range

Features

  • In-line one-pipe installation: Inlet and outlet ports sit at the same level with identical pipe dimensions for compact vertical mounting.
  • Three wetted-material tiers: CR combines cast-iron pump heads/bases with EN 1.4301 (AISI 304) hydraulics, CRI uses EN 1.4408 (CF 8M) pump heads/bases with AISI 304 internals, and CRN puts all wetted parts in EN 1.4401 / EN 1.4408 (AISI 316 / CF 8M) stainless steel.
  • Cartridge mechanical shaft seal: Fitted as standard with an HQQE or HQQV balanced O-ring cartridge seal (silicon carbide/silicon carbide faces with EPDM or FKM elastomers) for service without disassembling the chamber stack.
  • IE4 motor efficiency: Equipped with 2-pole totally enclosed fan-cooled Grundfos MG motors (0.37 to 18.5 kW) or Innomotics motors (22 to 200 kW) in IP55 enclosure, insulation class F.
  • Thrust-handling device (THD): Factory-fitted on motors 75 kW and larger so standard ball bearings absorb axial impeller thrust.
  • ErP ecodesign compliance: Benchmark MEI >= 0.70 across sizes CR 1-3, 3-3, 10-3 through 255-3.

Grundfos CR vertical multistage pump sectional cutaway showing staybolts, chamber stack, and cartridge seal

Technical Data

Product range and hydraulic limits across sizes 1s through 20 (50 Hz IEC):

Pump Size1s135101520
Rated flow rate [m³/h]0.8135101520
Flow rate range [m³/h]0.3 - 1.10.7 - 2.41.2 - 4.52.5 - 8.55 - 139 - 2411 - 29
Liquid temperature [°C] (standard)-20 to +120-20 to +120-20 to +120-20 to +120-20 to +120-20 to +120-20 to +120
Max. pump efficiency [%]35485866707272
Max. operating pressure [bar]21222424222325
High pressure on request (CRN) [bar]-474147444748
Motor power [kW]0.37 - 1.10.37 - 2.20.37 - 30.37 - 5.50.37 - 7.51.1 - 151.1 - 18.5
Flange connection (standard)DN 25 / DN 32DN 25 / DN 32DN 25 / DN 32DN 25 / DN 32DN 40DN 50DN 50
Oval flange (CR, BSP)Rp 1Rp 1Rp 1Rp 1 1/4Rp 1 1/4Rp 2Rp 2
PJE coupling (CRI/CRN)DN 32 (48.3 mm)DN 32 (48.3 mm)DN 32 (48.3 mm)DN 32 (48.3 mm)DN 50 (60.3 mm)DN 50 (60.3 mm)DN 50 (60.3 mm)

Product range and hydraulic limits across heavy-duty sizes 32 through 255 (50 Hz IEC):

Pump Size32456495125155185215255
Rated flow rate [m³/h]32456495125155185215255
Flow rate range [m³/h]15 - 4022 - 5830 - 8545 - 12060 - 16075 - 20092 - 240108 - 280128 - 330
Min. liquid temperature [°C]-30-30-30-20-20-20-20-20-20
Max. liquid temperature [°C]120120120120120120120120120
Max. pump efficiency [%]787980818282828484
Max. pressure [bar] (standard)283322363939353228
High pressure on request (CRN) [bar]504941------
Motor power [kW]1.5 - 303 - 454 - 455.5 - 9011 - 13211 - 16018.5 - 20022 - 20030 - 200
Flange connectionDN 65DN 80DN 100DN 100DN 150DN 150DN 200DN 200DN 200
PJE coupling (CRN)DN 80 (88.9 mm)DN 100 (114.3 mm)DN 100 (114.3 mm)DN 100 (114.3 mm)DN 150 (168.3 mm)DN 150 (168.3 mm)DN 200 (219.1 mm)DN 200 (219.1 mm)DN 200 (219.1 mm)

Note: Special versions extend liquid temperatures down to -40 °C and up to +180 °C (oils up to +240 °C) on request. For CR 95-155, standard max operating pressure is 25 bar (CRN 95-155 up to 40 bar).

Grundfos CR, CRI, CRN 50 Hz hydraulic performance range chart

Materials and Construction

Wetted and structural materials for CR, CRI, and CRN 1s–20:

ComponentCR 1s–20CRI 1s–20CRN 1s–20
Pump headGrey cast iron EN-GJL-200Stainless steel EN 1.4408 (CF 8M)Stainless steel EN 1.4408 (CF 8M)
BaseGrey cast iron EN-GJL-250Stainless steel EN 1.4408 (CF 8M)Stainless steel EN 1.4408 (CF 8M)
Impeller, chamber & sleeveStainless steel EN 1.4301 (AISI 304)Stainless steel EN 1.4301 (AISI 304)Stainless steel EN 1.4401 (AISI 316)
Pump shaft1.4401 (1s–5) / 1.4057 (10–20)1.4401 (1s–5) / 1.4057 (10–20)1.4401 (1s–5) / 1.4460 (10–20)
Neck ringPTFEPTFEPTFE
Shaft seal facesSilicon carbide / silicon carbideSilicon carbide / silicon carbideSilicon carbide / silicon carbide
Elastomers (O-rings)EPDM or FKMEPDM or FKMEPDM or FKM

For sizes 32–64, CR uses ductile cast iron EN-GJS-500-7 pump heads/bases with carbon-graphite-filled PTFE neck rings, while CRN 32–64 uses EN 1.4408 (CF 8M) heads/bases and EN 1.4462 duplex shafts. For sizes 95–255, neck rings upgrade to PEEK, bearing rings to tungsten carbide/tungsten carbide, and shafts (125–255) to duplex stainless steel EN 1.4462.

Shaft Seal Operating Limits

Standard balanced cartridge shaft seals (HQQE/HQQV/HQBE/HQBV) cover both 0.37–55 kW and 75–200 kW motor ranges:

Standard Shaft SealDescriptionLiquid Temperature [°C]
HQQEO-ring cartridge, balanced, silicon carbide / silicon carbide, EPDM-40 to +120
HQQVO-ring cartridge, balanced, silicon carbide / silicon carbide, FKM-20 to +90
HQBEO-ring cartridge, balanced, silicon carbide / carbon, EPDM0 to 120
HQBVO-ring cartridge, balanced, silicon carbide / carbon, FKM0 to 90

Connections and Ordering Code

Grundfos CR, CRI, CRN oval BSP flange, DIN flange, and PJE coupling base connections

Grundfos type key example (CRE 32-3-2 A-F-A-E-HQQE):

  • Type range & flow: CR, CRI, or CRN (E denotes integrated frequency converter), followed by rated flow (1s to 255 m³/h), number of impellers, and reduced-diameter impellers.
  • Pipe connection: A (Oval flange), B (NPT thread), CA (FlexiClamp), CX (TriClamp), F (DIN flange), FE (EN 1092-1 type E), G (ANSI flange), J (JIS flange), P (PJE Victaulic-type coupling).
  • Supply voltage (50 Hz): 3 x 220-230/380-400 V (0.37–1.5 kW), 3 x 380-400/660-690 V (2.2–18.5 kW), 3 x 380-420/660-725 V (22–200 kW), or single-phase 1 x 220-230/240 V (0.37–2.2 kW).

Specify Grundfos CR, CRI, or CRN model code, stage count, connection type, shaft seal variant, supply voltage, and quantity when requesting a quotation.